Cart

Your Shopping Cart is empty.

Continue Shopping

AC 110V 220V Infinite Cycle Delay Timing Timer Relay Turn ON/OFF Switch Module

$5.94  $3.56

Up To 50% Off,30-Day Returns
Add to Wish
  • All returns accepted: Returns Accepted
  • Brand: Unbranded/Generic
  • Condition: New
  • Country/Region of Manufacture: China
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply
  • Model: time relay module
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Restocking Fee: No
  • Return shipping will be paid by: Seller
  • Type: Delay Switch module
  • Working voltage: AC100V-250V
  • 1000 Units in Stock
  • Location:Dongguan, Guangdong
  • Ships to:Worldwide
  • Condition:New
  • heart Popularity - 5625 views, 803.6 views per day, 7 days on eBay. Super high amount of views. 44 sold.
  • usd Price - Avg: $0.00, Low: $0.00, High: $0.00. Best quality when compared to PicClick similar items.
  • star Seller - + items sold. 0% negative feedback. Great seller with very good positive feedback and over 50 ratings.
Welcome to Happy_guy<br>You may also like, welcome use "add to basket to buy"<br>Description<br>Tips:<br>If you need Large quantity, please contact us, we can wholesales.<br>Features:<br>with the start / stop function, after the start of the module into the infinite loop mode, the relay work in accordance with the set time.<br>Parameter:<br>Voltage: AC 100V-250V, can be used for 100V/110V/120V/127V/220V/230V/240V power.<br>Power consumption: <1.0W<br>Output: active output, output voltage and input voltage the same. Maximum not more than 10A.<br>Life: 100 thousand times<br>Input: passive switch input, after the start of the green light first, stop after the red light<br>Time range: 0.5 seconds -1000 minutes<br>Time accuracy: range Max * 0.001, or resolution of 1000.<br>Input (start button): no source switch input, after the start of the green light first, stop to stay in the red light.<br>- starting the input is not necessary, you can connect the two terminals with a short wire,<br>so that the power will be started on the infinite loop, no buttons.<br>Dimensions: length 88mm * width 38mm * high 22mm below<br>Screw hole: center distance 83mm * 33mm, aperture 3.2mm<br>Terminal:<br><--L power L line (fireWire) input<br><--N power N line (zero line) input<br>-->Ouput N, load N line<br>-->Ouput: L1, load L line<br>most appliances do not need to strictly distinguish the LN line<br>-->LNC L line output normally closed, generally do not connect.<br>Operating instructions<br>:<br>1.ON time setting:<br>RUN TIME under the identification of the potentiometer adjustment time, clockwise for the increase in length, counterclockwise to shorten the length of time.<br>Potentiometer allocated code switch set to the left time range. The adjustable range of the adjustable resistor is 0-100; the dial range is 0-1000.<br>The potentiometer allocated code switch unit set right. Dial down to Sec. indicating unit for seconds; dial up to Min. to indicate unit for minute.<br>2.OFF time setting:<br>OFF TIME under the identification of the potentiometer adjustment time, clockwise for the increase in length, counterclockwise to shorten the length of time.<br>Potentiometer allocated code switch set to the left time range. The adjustable range of the adjustable resistor is 0-100; the dial range is 0-1000.<br>The potentiometer allocated code switch unit set right. Dial down to Sec. indicating unit for seconds; dial up to Min. to indicate unit for minute.<br>3 start button:<br>Access to the reset button, click, switch to the green light, indicating that the running state, the module will automatically set in accordance with the running time and the length of time to stop working, infinite loop. Click the start button again, the module will switch to red light, said to be in a stopped state.<br>4 time set example:<br>Requirements: connect 20 seconds, disconnect 30 minutes, infinite loop.<br>Set up:<br>(1). Set the run time range down to 0-100;<br>(2) set the run time unit down to seconds;<br>(3) turn the running time potentiometer to the position of the, which is the position of the left 20/100;<br>(4). Set the stop time range to 0-100;<br>(5) set the stop time unit to minutes;<br>(6) turn the stop time potentiometer to the position of the 30, which is the position of the 30/100 from the left;<br>Application<br>:<br>For cycle control, or equipment, product aging test repeated power on/off.<br>Notes:<br>1. If need start button, the button capacity need above 0.1A.<br>2. AC power, beware safety<br>Package Include:<br>Relay module  x 1pcs<br>Payment<br>We only accept payment via Paypal.<br>The buyer is responsible for any applicable import duties and local taxes.<br>Usually there's no any charges for small parcel. But please verify with your customs before making your purchase.<br>Delivery details<br>The items will be shipped within 1~2 working days after your payment is received and cleared.(excluding Saturday, Sunday & Holiday)<br>All items will be shipped to your Paypal address, so please make sure to provide us with